HVAC Service & Plumber in Parkville, MO

Close-up of man hands setting the temperature of water

A trusted HVAC and plumbing technician is important for maintaining a comfortable living space. At Buckner’s Heating, Cooling, & Plumbing, we’re proud to offer the comprehensive HVAC and plumbing solutions that Parkville families need to keep their properties safe, comfortable, and fully functional.

With over 40 years of local service experience and 100% satisfaction guaranteed, you can rest assured that you’ll always receive long-lasting home service solutions you can rely on for years to come.

Heating & Cooling Services

Our team specializes in servicing heating and cooling equipment to ensure your home remains comfortable all year. We can help with:

Heating

Parkville families know firsthand how important it is to have a fully functioning heating system. At Buckner’s, our team can service any make or model heating system, including gas and electric furnaces, heat pumps, and geothermal units. We offer:

Cooling

With hot, muggy, wet weather conditions, Parkville families need reliable cooling equipment to get through the stifling summer season. Our air conditioning experts have experience servicing all types of cooling equipment, including central AC systems, ductless mini-splits, and heat pumps. We are here to help with:

Whatever your HVAC needs may be, Buckner’s has the team you can trust to get the job done right. Book heating and cooling services in Parkville by calling (816) 436-1244!

Schedule Your Service Today

Indoor Air Quality Solutions

Poor indoor air quality is one of the leading health concerns for U.S. families, according to the Environmental Protection Agency. Buckner’s takes your home safety and comfort seriously, delivering powerful indoor air quality solutions designed to eliminate harmful contaminants from your air supply:

  • Air purifiers: Remove radon, asbestos, viruses, and bacteria from your air supply.
  • Air cleaners: Eliminate airborne irritants to alleviate allergies and asthma symptoms in your household.
  • Humidifiers: Maintain moisture levels in your home.
  • Dehumidifiers: Remove excess humidity from your indoor environment.
  • Air scrubbers: Remove common airborne allergens like pollen, dust, and pet dander.

Breathe cleaner, healthier air indoors with help from Buckner’s. Call (816) 436-1244 to get indoor air quality services today!

Home Plumbing Services

Buckner’s is proud to offer a comprehensive range of sewer and drain services, including hydro jetting solutions to address severe blockages hiding deep within your drain and sewer system. With our state-of-the-art equipment and experienced technicians, we can clear clogged drains and sewers swiftly and efficiently, restoring proper flow and preventing future blockages.

We also specialize in kitchen and bathroom plumbing, providing expert installations, repairs, and renovations to enhance the functionality and aesthetic of your space. Whether you need new fixtures installed, leaky pipes repaired, water treatment services, or remodeling an entire space, we ensure top-quality workmanship and customer satisfaction at every step.

Water Heater Installation & Repair

Hot water is necessary in every modern home, and Buckner’s has the team you need to ensure reliable access to a hot water supply. Our team has experience servicing both standard tank and tankless water heater systems. We can assist with:

Request water heater services in Parkville by calling us at (816) 436-1244 today.

Why Choose Buckner’s?

Since 1983, Buckner’s has delivered the fast, reliable HVAC and plumbing solutions that Parkville families trust to keep their homes safe and comfortable all year. With 100% satisfaction guaranteed and after-hours service availability for emergencies, we’re confident in our team’s ability to deliver the prompt, professional solutions that Parkville families need to keep their essential systems working properly for the long term.

Don’t settle for subpar service for your HVAC and plumbing. Call (816) 436-1244 or contact us online to schedule with the team Parkville residents trust!

 

Recent Jobs and Reviews in Parkville, MO

Job Locations and Reviews

Installed 50-gallon gas water heater with thermal expansion tank mounted at top of unit. Replaced and installed 3/4-inch pressure reducing valve and repaired approximately 3 feet of water supply line. Connected yellow flexible gas line to unit base with shutoff valve, ran copper piping with brass fittings for hot and cold water connections, and installed white PVC drain line at floor level. All plumbing connections secured and tested for proper operation and pressure regulation.
Installed 50-gallon gas water heater with thermal expansion tank mounted at top of unit. Replaced and installed 3/4-inch pressure reducing valve and repaired approximately 3 feet of water supply line. Connected yellow flexible gas line to unit base with shutoff valve, ran copper piping with brass fittings for hot and cold water connections, and installed white PVC drain line at floor level. All plumbing connections secured and tested for proper operation and pressure regulation.
Gideon C.
Gideon C. Checked in
Installed 50-gallon gas water heater with thermal expansion tank mounted at top of unit. Replaced and installed 3/4-inch pressure reducing valve and repaired approximately 3 feet of water supply line. Connected yellow flexible gas line to unit base with shutoff valve, ran copper piping with brass fittings for hot and cold water connections, and installed white PVC drain line at floor level. All plumbing connections secured and tested for proper operation and pressure regulation.
Parkville, MO 64152
Responded to shower valve malfunction where homeowner had replaced cartridge but experienced severe water spray due to cartridge ejecting from valve body upon water activation. Diagnosed improper cartridge installation and missing or damaged retaining clip that prevented cartridge from seating correctly in valve housing. Removed incorrectly installed cartridge, inspected valve body for damage, and reinstalled cartridge with proper retaining hardware to manufacturer specifications. Tested system operation under full water pressure to verify secure cartridge retention and proper flow control without leaks or spray.
Responded to shower valve malfunction where homeowner had replaced cartridge but experienced severe water spray due to cartridge ejecting from valve body upon water activation. Diagnosed improper cartridge installation and missing or damaged retaining clip that prevented cartridge from seating correctly in valve housing. Removed incorrectly installed cartridge, inspected valve body for damage, and reinstalled cartridge with proper retaining hardware to manufacturer specifications. Tested system operation under full water pressure to verify secure cartridge retention and proper flow control without leaks or spray.
Steaven B.
Steaven B. Checked in
Responded to shower valve malfunction where homeowner had replaced cartridge but experienced severe water spray due to cartridge ejecting from valve body upon water activation. Diagnosed improper cartridge installation and missing or damaged retaining clip that prevented cartridge from seating correctly in valve housing. Removed incorrectly installed cartridge, inspected valve body for damage, and reinstalled cartridge with proper retaining hardware to manufacturer specifications. Tested system operation under full water pressure to verify secure cartridge retention and proper flow control without leaks or spray.
Parkville, MO 64152
Performed plumbing maintenance on residential toilet system. Inspected internal tank components including flush valve assembly, fill valve mechanism, and refill tube connections. All components were functioning properly with flush valve, flapper, and ballcock assembly in good working condition. Verified proper water flow and tank refill operation.
Performed plumbing maintenance on residential toilet system. Inspected internal tank components including flush valve assembly, fill valve mechanism, and refill tube connections. All components were functioning properly with flush valve, flapper, and ballcock assembly in good working condition. Verified proper water flow and tank refill operation.
Mayrel S.
Mayrel S. Checked in
Performed plumbing maintenance on residential toilet system. Inspected internal tank components including flush valve assembly, fill valve mechanism, and refill tube connections. All components were functioning properly with flush valve, flapper, and ballcock assembly in good working condition. Verified proper water flow and tank refill operation.
Parkville, MO 64152
Installed 50-gallon STATE gas water heater with thermal expansion tank and ball valve shut-off on water inlet line. Removed and disposed of two existing water heaters from the property. Re-piped flue venting system to accommodate single water heater configuration and removed excess gas supply line that previously served secondary unit. Installed humidifier shut-off valve integrated with water heater system. Connected yellow flexible gas line to unit with proper fittings and routed copper supply and discharge piping with soldered connections. Mounted blue thermal expansion tank to system per code requirements. All connections tested and verified operational. Installation includes one-year labor warranty and six-year manufacturer warranty coverage.
Installed 50-gallon STATE gas water heater with thermal expansion tank and ball valve shut-off on water inlet line. Removed and disposed of two existing water heaters from the property. Re-piped flue venting system to accommodate single water heater configuration and removed excess gas supply line that previously served secondary unit. Installed humidifier shut-off valve integrated with water heater system. Connected yellow flexible gas line to unit with proper fittings and routed copper supply and discharge piping with soldered connections. Mounted blue thermal expansion tank to system per code requirements. All connections tested and verified operational. Installation includes one-year labor warranty and six-year manufacturer warranty coverage.
Gideon C.
Gideon C. Checked in
Installed 50-gallon STATE gas water heater with thermal expansion tank and ball valve shut-off on water inlet line. Removed and disposed of two existing water heaters from the property. Re-piped flue venting system to accommodate single water heater configuration and removed excess gas supply line that previously served secondary unit. Installed humidifier shut-off valve integrated with water heater system. Connected yellow flexible gas line to unit with proper fittings and routed copper supply and discharge piping with soldered connections. Mounted blue thermal expansion tank to system per code requirements. All connections tested and verified operational. Installation includes one-year labor warranty and six-year manufacturer warranty coverage.
Parkville, MO 64152
Performed comprehensive maintenance on a Rinnai RH-180 tankless water heater involving complete disassembly and manual cleaning of the heat exchanger assembly. The heat exchanger exhibited significant corrosion and oxidation buildup on the copper coil tubes and surrounding metallic components, with visible green patina indicating prolonged exposure to moisture and mineral deposits. Removed all four parallel cylindrical tubes from the housing, thoroughly cleaned the spiral fins and connecting points to remove accumulated scale and corrosion, then reassembled the unit to restore optimal heat transfer efficiency and extend equipment lifespan.
Performed comprehensive maintenance on a Rinnai RH-180 tankless water heater involving complete disassembly and manual cleaning of the heat exchanger assembly. The heat exchanger exhibited significant corrosion and oxidation buildup on the copper coil tubes and surrounding metallic components, with visible green patina indicating prolonged exposure to moisture and mineral deposits. Removed all four parallel cylindrical tubes from the housing, thoroughly cleaned the spiral fins and connecting points to remove accumulated scale and corrosion, then reassembled the unit to restore optimal heat transfer efficiency and extend equipment lifespan.
Steaven B.
Steaven B. Checked in
Performed comprehensive maintenance on a Rinnai RH-180 tankless water heater involving complete disassembly and manual cleaning of the heat exchanger assembly. The heat exchanger exhibited significant corrosion and oxidation buildup on the copper coil tubes and surrounding metallic components, with visible green patina indicating prolonged exposure to moisture and mineral deposits. Removed all four parallel cylindrical tubes from the housing, thoroughly cleaned the spiral fins and connecting points to remove accumulated scale and corrosion, then reassembled the unit to restore optimal heat transfer efficiency and extend equipment lifespan.
Parkville, MO 64152
Successfully installed a 50-gallon State ProLine commercial-grade gas water heater with thermal expansion tank in the basement utility room. All copper supply line connections were completed at the top of the unit with appropriate shut-off valves, and the yellow flexible gas line was properly connected to the gas control valve assembly at the base. The installation includes all required safety labels, proper venting, and the unit was tested for proper operation upon completion.
Successfully installed a 50-gallon State ProLine commercial-grade gas water heater with thermal expansion tank in the basement utility room. All copper supply line connections were completed at the top of the unit with appropriate shut-off valves, and the yellow flexible gas line was properly connected to the gas control valve assembly at the base. The installation includes all required safety labels, proper venting, and the unit was tested for proper operation upon completion.
Gideon C.
Gideon C. Checked in
Successfully installed a 50-gallon State ProLine commercial-grade gas water heater with thermal expansion tank in the basement utility room. All copper supply line connections were completed at the top of the unit with appropriate shut-off valves, and the yellow flexible gas line was properly connected to the gas control valve assembly at the base. The installation includes all required safety labels, proper venting, and the unit was tested for proper operation upon completion.
Parkville, MO 64152
Conducted on-site assessment of existing 6-year-old water heater system in basement mechanical room for replacement estimate. Unit currently operational with standard copper supply line connections, exhaust venting, and proximity to expansion tank and HVAC equipment. Documented existing installation configuration including top-mounted pipe connections, metal exhaust ducting, and surrounding utility infrastructure to provide accurate replacement specifications and ensure proper sizing for new water heater installation.
Conducted on-site assessment of existing 6-year-old water heater system in basement mechanical room for replacement estimate. Unit currently operational with standard copper supply line connections, exhaust venting, and proximity to expansion tank and HVAC equipment. Documented existing installation configuration including top-mounted pipe connections, metal exhaust ducting, and surrounding utility infrastructure to provide accurate replacement specifications and ensure proper sizing for new water heater installation.
Tommy W.
Tommy W. Checked in
Conducted on-site assessment of existing 6-year-old water heater system in basement mechanical room for replacement estimate. Unit currently operational with standard copper supply line connections, exhaust venting, and proximity to expansion tank and HVAC equipment. Documented existing installation configuration including top-mounted pipe connections, metal exhaust ducting, and surrounding utility infrastructure to provide accurate replacement specifications and ensure proper sizing for new water heater installation.
Parkville, MO 64152
Responded to leak detection request following HVAC contractor observation of water intrusion. Investigated interior plumbing system through wall access point, inspecting PVC supply lines with copper fittings and red-handled shutoff valve for signs of active leaks or moisture damage. Examined exterior hose bib and associated connections, checking valve body, handle assembly, and nearby bundled service lines for potential leak sources. Documented conditions of both interior wall cavity plumbing and exterior spigot installation with photographic evidence to assist in determining leak origin point between indoor pipe system and outdoor faucet assembly.
Responded to leak detection request following HVAC contractor observation of water intrusion. Investigated interior plumbing system through wall access point, inspecting PVC supply lines with copper fittings and red-handled shutoff valve for signs of active leaks or moisture damage. Examined exterior hose bib and associated connections, checking valve body, handle assembly, and nearby bundled service lines for potential leak sources. Documented conditions of both interior wall cavity plumbing and exterior spigot installation with photographic evidence to assist in determining leak origin point between indoor pipe system and outdoor faucet assembly.
Tommy W.
Tommy W. Checked in
Responded to leak detection request following HVAC contractor observation of water intrusion. Investigated interior plumbing system through wall access point, inspecting PVC supply lines with copper fittings and red-handled shutoff valve for signs of active leaks or moisture damage. Examined exterior hose bib and associated connections, checking valve body, handle assembly, and nearby bundled service lines for potential leak sources. Documented conditions of both interior wall cavity plumbing and exterior spigot installation with photographic evidence to assist in determining leak origin point between indoor pipe system and outdoor faucet assembly.
Parkville, MO 64152
Responded to service call for reverse osmosis system repair where homeowner damaged a 3/8" elbow fitting during filter replacement. Replaced broken fitting with new brass compression elbow and reassembled RO filter system connections ensuring proper water flow direction and secure leak-free joints. Verified system operation, checked for leaks at all connection points, and confirmed proper filtration sequence through multi-stage filter housings and pressure tank.
Responded to service call for reverse osmosis system repair where homeowner damaged a 3/8" elbow fitting during filter replacement. Replaced broken fitting with new brass compression elbow and reassembled RO filter system connections ensuring proper water flow direction and secure leak-free joints. Verified system operation, checked for leaks at all connection points, and confirmed proper filtration sequence through multi-stage filter housings and pressure tank.
Tommy W.
Tommy W. Checked in
Responded to service call for reverse osmosis system repair where homeowner damaged a 3/8" elbow fitting during filter replacement. Replaced broken fitting with new brass compression elbow and reassembled RO filter system connections ensuring proper water flow direction and secure leak-free joints. Verified system operation, checked for leaks at all connection points, and confirmed proper filtration sequence through multi-stage filter housings and pressure tank.
Parkville, MO 64152
Parkville, MO - Responded to a clogged kitchen sink drain. Upon inspection, accessed the dual-sink plumbing assembly beneath the cabinet and identified blockage in the P-trap system. Disassembled the white PVC drain configuration, cleared accumulated debris from the P-trap and tailpiece connections, and reassembled the drainage system to restore proper flow and functionality.
Tommy W.
Tommy W. Checked in
Responded to a clogged kitchen sink drain. Upon inspection, accessed the dual-sink plumbing assembly beneath the cabinet and identified blockage in the P-trap system. Disassembled the white PVC drain configuration, cleared accumulated debris from the P-trap and tailpiece connections, and reassembled the drainage system to restore proper flow and functionality.
Parkville, MO 64152
Removed and disposed of existing State brand tank-style water heater showing significant rust corrosion at top connections. Installed Rinnai RXP199 condensing tankless water heater with 96% efficiency rating and 11.00 GPM capacity in utility area. Ran approximately 15 feet of hot and cold Aquapex waterlines from main supply to new unit location. Installed gas supply line using black iron pipe with required tee fittings and two 90-degree elbows, including gas dirt leg and emergency shut-off valve per code requirements. Installed 2-inch PVC venting system for exhaust and fresh air intake, terminating appropriately for optimal unit operation and combustion air requirements. Capped existing gas lines and venting from previous water heater installation. Ran condensate drain line to floor drain with proper air vent installed below unit to prevent trap siphoning. Installed Rinnai-provided check valve on cold water line to enable hot water recirculation system, allowing hot water to return thr
Removed and disposed of existing State brand tank-style water heater showing significant rust corrosion at top connections. Installed Rinnai RXP199 condensing tankless water heater with 96% efficiency rating and 11.00 GPM capacity in utility area. Ran approximately 15 feet of hot and cold Aquapex waterlines from main supply to new unit location. Installed gas supply line using black iron pipe with required tee fittings and two 90-degree elbows, including gas dirt leg and emergency shut-off valve per code requirements. Installed 2-inch PVC venting system for exhaust and fresh air intake, terminating appropriately for optimal unit operation and combustion air requirements. Capped existing gas lines and venting from previous water heater installation. Ran condensate drain line to floor drain with proper air vent installed below unit to prevent trap siphoning. Installed Rinnai-provided check valve on cold water line to enable hot water recirculation system, allowing hot water to return thr
Steaven B.
Steaven B. Checked in
Removed and disposed of existing State brand tank-style water heater showing significant rust corrosion at top connections. Installed Rinnai RXP199 condensing tankless water heater with 96% efficiency rating and 11.00 GPM capacity in utility area. Ran approximately 15 feet of hot and cold Aquapex waterlines from main supply to new unit location. Installed gas supply line using black iron pipe with required tee fittings and two 90-degree elbows, including gas dirt leg and emergency shut-off valve per code requirements. Installed 2-inch PVC venting system for exhaust and fresh air intake, terminating appropriately for optimal unit operation and combustion air requirements. Capped existing gas lines and venting from previous water heater installation. Ran condensate drain line to floor drain with proper air vent installed below unit to prevent trap siphoning. Installed Rinnai-provided check valve on cold water line to enable hot water recirculation system, allowing hot water to return thr
Parkville, MO 64152
Responded to service call for tanked water heater with reported crust formation at top of unit, water pooling, and improper flue venting. Upon inspection in basement, confirmed mineral deposit buildup on top of water heater and evidence of condensation issues related to compromised venting system. Assessed flue pipe configuration and determined improper draft was causing combustion gases to condense, leading to corrosion and water accumulation. Performed diagnostic evaluation of venting components and water heater operation. Addressed drainage concerns and documented existing conditions showing water staining on floor around unit. Completed necessary repairs to restore proper venting function and resolve moisture infiltration issues.
Responded to service call for tanked water heater with reported crust formation at top of unit, water pooling, and improper flue venting. Upon inspection in basement, confirmed mineral deposit buildup on top of water heater and evidence of condensation issues related to compromised venting system. Assessed flue pipe configuration and determined improper draft was causing combustion gases to condense, leading to corrosion and water accumulation. Performed diagnostic evaluation of venting components and water heater operation. Addressed drainage concerns and documented existing conditions showing water staining on floor around unit. Completed necessary repairs to restore proper venting function and resolve moisture infiltration issues.
Tommy W.
Tommy W. Checked in
Responded to service call for tanked water heater with reported crust formation at top of unit, water pooling, and improper flue venting. Upon inspection in basement, confirmed mineral deposit buildup on top of water heater and evidence of condensation issues related to compromised venting system. Assessed flue pipe configuration and determined improper draft was causing combustion gases to condense, leading to corrosion and water accumulation. Performed diagnostic evaluation of venting components and water heater operation. Addressed drainage concerns and documented existing conditions showing water staining on floor around unit. Completed necessary repairs to restore proper venting function and resolve moisture infiltration issues.
Parkville, MO 64152
Completed comprehensive plumbing inspection of kitchen sink system and garbage disposal unit. All components including stainless steel sink drain assembly, chrome strainer basket, white PVC P-trap, flexible braided supply lines, shutoff valves, and garbage disposal with corrugated drain hose were examined and found to be properly installed and functioning within normal parameters.
Completed comprehensive plumbing inspection of kitchen sink system and garbage disposal unit. All components including stainless steel sink drain assembly, chrome strainer basket, white PVC P-trap, flexible braided supply lines, shutoff valves, and garbage disposal with corrugated drain hose were examined and found to be properly installed and functioning within normal parameters.
Steaven B.
Steaven B. Checked in
Completed comprehensive plumbing inspection of kitchen sink system and garbage disposal unit. All components including stainless steel sink drain assembly, chrome strainer basket, white PVC P-trap, flexible braided supply lines, shutoff valves, and garbage disposal with corrugated drain hose were examined and found to be properly installed and functioning within normal parameters.
Parkville, MO 64152
Responded to service call for clogged floor drain in garage and leaking outside faucet. Upon inspection, accessed plumbing system through ceiling access point to diagnose drainage issue and locate source of exterior faucet leak. Cut access opening in ceiling to expose copper supply lines and structural plumbing components for proper assessment and repair access. Documented conditions of exposed plumbing infrastructure and framing for repair recommendations.
Responded to service call for clogged floor drain in garage and leaking outside faucet. Upon inspection, accessed plumbing system through ceiling access point to diagnose drainage issue and locate source of exterior faucet leak. Cut access opening in ceiling to expose copper supply lines and structural plumbing components for proper assessment and repair access. Documented conditions of exposed plumbing infrastructure and framing for repair recommendations.
Steaven B.
Steaven B. Checked in
Responded to service call for clogged floor drain in garage and leaking outside faucet. Upon inspection, accessed plumbing system through ceiling access point to diagnose drainage issue and locate source of exterior faucet leak. Cut access opening in ceiling to expose copper supply lines and structural plumbing components for proper assessment and repair access. Documented conditions of exposed plumbing infrastructure and framing for repair recommendations.
Parkville, MO 64152
Responded to emergency call for State ProLine tanked water heater experiencing internal failure with significant water leakage from bottom of unit. Upon arrival, confirmed water source had been shut off by customer. Conducted visual inspection and auditory assessment, detecting fountain-like sound indicating internal tank rupture. Inspected basement utility area installation, noting unit was approximately 5-6 years old with copper supply lines, proper venting through galvanized duct, and standard connections. Documented equipment condition through photographs showing water heater alongside existing water softener system. Evaluated extent of damage and determined tank breach required full water heater replacement. Provided customer with repair options and recommendations for new unit installation.
Responded to emergency call for State ProLine tanked water heater experiencing internal failure with significant water leakage from bottom of unit. Upon arrival, confirmed water source had been shut off by customer. Conducted visual inspection and auditory assessment, detecting fountain-like sound indicating internal tank rupture. Inspected basement utility area installation, noting unit was approximately 5-6 years old with copper supply lines, proper venting through galvanized duct, and standard connections. Documented equipment condition through photographs showing water heater alongside existing water softener system. Evaluated extent of damage and determined tank breach required full water heater replacement. Provided customer with repair options and recommendations for new unit installation.
Gideon C.
Gideon C. Checked in
Responded to emergency call for State ProLine tanked water heater experiencing internal failure with significant water leakage from bottom of unit. Upon arrival, confirmed water source had been shut off by customer. Conducted visual inspection and auditory assessment, detecting fountain-like sound indicating internal tank rupture. Inspected basement utility area installation, noting unit was approximately 5-6 years old with copper supply lines, proper venting through galvanized duct, and standard connections. Documented equipment condition through photographs showing water heater alongside existing water softener system. Evaluated extent of damage and determined tank breach required full water heater replacement. Provided customer with repair options and recommendations for new unit installation.
Parkville, MO 64152
Completed on-site assessment for 50-gallon water heater replacement in basement location. Evaluated existing plumbing configuration including water softener system, copper supply lines, pressure regulation valve assembly with gauge, and connection points to determine installation requirements for customer-preferred AO Smith unit.
Completed on-site assessment for 50-gallon water heater replacement in basement location. Evaluated existing plumbing configuration including water softener system, copper supply lines, pressure regulation valve assembly with gauge, and connection points to determine installation requirements for customer-preferred AO Smith unit.
Mayrel S.
Mayrel S. Checked in
Completed on-site assessment for 50-gallon water heater replacement in basement location. Evaluated existing plumbing configuration including water softener system, copper supply lines, pressure regulation valve assembly with gauge, and connection points to determine installation requirements for customer-preferred AO Smith unit.
Parkville, MO 64152
Responded to service call for garbage disposal leak and insufficient hot water production. Inspected under-sink plumbing configuration including black garbage disposal unit connected to PVC drain pipes with P-trap assembly. No active leaks were observed during inspection, and all connections appeared secure with normal working condition confirmed.
Responded to service call for garbage disposal leak and insufficient hot water production. Inspected under-sink plumbing configuration including black garbage disposal unit connected to PVC drain pipes with P-trap assembly. No active leaks were observed during inspection, and all connections appeared secure with normal working condition confirmed.
Gideon C.
Gideon C. Checked in
Responded to service call for garbage disposal leak and insufficient hot water production. Inspected under-sink plumbing configuration including black garbage disposal unit connected to PVC drain pipes with P-trap assembly. No active leaks were observed during inspection, and all connections appeared secure with normal working condition confirmed.
Parkville, MO 64152
Replaced two deteriorated shut-off valves under sink in basement. Installed new chrome shut-off valves after removing significant mineral deposits from existing plumbing connections. Tested water flow and confirmed proper operation with no leaks.
Replaced two deteriorated shut-off valves under sink in basement. Installed new chrome shut-off valves after removing significant mineral deposits from existing plumbing connections. Tested water flow and confirmed proper operation with no leaks.
Tommy W.
Tommy W. Checked in
Replaced two deteriorated shut-off valves under sink in basement. Installed new chrome shut-off valves after removing significant mineral deposits from existing plumbing connections. Tested water flow and confirmed proper operation with no leaks.
Parkville, MO 64152
Responded to service call for water heater leaking from relief valve. Diagnostic testing revealed excessive system pressure at 100-110 PSI, well above normal operating range. Adjusted pressure regulator and verified proper T&P valve operation to resolve the leak issue.
Responded to service call for water heater leaking from relief valve. Diagnostic testing revealed excessive system pressure at 100-110 PSI, well above normal operating range. Adjusted pressure regulator and verified proper T&P valve operation to resolve the leak issue.
Mayrel S.
Mayrel S. Checked in
Responded to service call for water heater leaking from relief valve. Diagnostic testing revealed excessive system pressure at 100-110 PSI, well above normal operating range. Adjusted pressure regulator and verified proper T&P valve operation to resolve the leak issue.
Parkville, MO 64152
Completed scheduled preventive plumbing maintenance which included tankless water heater flush and service of the water softener-filter system. Performed inspection of heating system components, ensuring proper operation of heat exchanger assembly, control board, and electrical connections. Conducted water quality testing using test strips to verify system performance and water parameters were within acceptable ranges.
Completed scheduled preventive plumbing maintenance which included tankless water heater flush and service of the water softener-filter system. Performed inspection of heating system components, ensuring proper operation of heat exchanger assembly, control board, and electrical connections. Conducted water quality testing using test strips to verify system performance and water parameters were within acceptable ranges.
Gideon C.
Gideon C. Checked in
Completed scheduled preventive plumbing maintenance which included tankless water heater flush and service of the water softener-filter system. Performed inspection of heating system components, ensuring proper operation of heat exchanger assembly, control board, and electrical connections. Conducted water quality testing using test strips to verify system performance and water parameters were within acceptable ranges.
Parkville, MO 64152

Buckner’s is better

Discover the Difference

Satisfaction Guaranteed

Our service is so good, we know you won’t be disappointed! That’s why we offer a 100% satisfaction guarantee.

Free Estimates

We want to take out the stress of finding an HVAC contractor, so you can count on us for free estimates.

Highly Trained Technicians

To provide the best service, all of our technicians receive ongoing training to keep their skills sharp.

Veteran-Led

We are proud to be a veteran-led company, and this shows in our commitment to our community.

Peace of Mind

Our team works hard to deliver top-quality heating and cooling solutions, so that you don’t have to worry.

After-Hours Service

HVAC problems can occur at the least convenient times, so we’re available around the clock to help out!

Satisfaction Guaranteed

Our service is so good, we know you won’t be disappointed! That’s why we offer a 100% satisfaction guarantee.

Free Estimates

We want to take out the stress of finding an HVAC contractor, so you can count on us for free estimates.

Highly Trained Technicians

To provide the best service, all of our technicians receive ongoing training to keep their skills sharp.

Veteran-Led

We are proud to be a veteran-led company, and this shows in our commitment to our community.

Peace of Mind

Our team works hard to deliver top-quality heating and cooling solutions, so that you don’t have to worry.

After-Hours Service

HVAC problems can occur at the least convenient times, so we’re available around the clock to help out!

See What Your Neighbors Are Saying.

Buckner’s installed a great system (heating & cooling) in one day at a great price compared to 3 other companies that provided proposals. They were efficient, polite, professional, and considerate in our home. I would highly recommend Buckners to everyone. Daniel led the 2-man team. Thank you both for the great work.

Ed C.

Ed C.

Got to us right away on a cold day! All the technicians were amazing! So happy for our new furnace we only had to wait 2 days for. Everyone from the 1st contact to the last cared about us and our needs. Service was EXCELLENT!

Maria G.

Maria G.